The system for handling solid waste and medical waste
Description
Installation for environmentally safe high-temperature thermal destruction and neutralization of waste allows to process up to 100 kg/h of medical waste classes A, B, C, and partly G, biological and bio-organic wastes, including the corpses of stray animals and birds, post-mortem waste, solid waste and industrial waste
Efficiency:
- Reduction of the initial mass of waste to 95%
- Characteristics of the ash residue - neutral substances, IV class of danger
- Purification of exhaust gases to European standards (Directive 2000/76/EC)
- Disinfection of waste from pathogenic microorganisms 100%
- The possibility of construction of the module in the site of waste generation
Characteristics
Number | Parameter | Value |
1 | 2 | 3 |
1 | A thermal decomposition chamber volume , liters | 1900 |
2 | Of recyclable waste ( 4440 kcal / kg ), kg / h | up to 100 |
3 | The principle of waste disposal | pyrolysis |
4 | Boot mode | cyclical |
5 | The primary source of heat energy | d / fuel |
6 | Fuel burner kg / h Weishaupt WL 20/2 Lamborghini ECO 3R | 5,9-16,8 1,2-3 |
7 | The maximum total fuel consumption , kg / h | 12 |
8 | Energy consumption, kWh / h, the maximum when the whole equipment including a nominal , operating at ambient temperatures> 20 ° C nominal , operating at ambient temperature <20 ° C. | not more than 19.6 15.1 9.7 |
9 | Type of current , voltage | 380 |
10 | The negative pressure in the pyrolysis chamber , Pa | 4000 |
11 | Temperature of pyrolysis , ° C | > 830 |
12 | Afterburner temperature pyrolysis , ° C | > 1000 |