1 Pumping station designed to supply industrial water from the highway to the cleaning apparatus of power boilers 221EOB002, 221EOB001 with increasing pressure from the mainline (0.2 ... 0.6 MPa) to the desired (22 MPa) with filtration of large mechanical inclusions.
2 Pumping Station has UHL4 climatic version according to GOST 15150 and must be operated at an ambient temperature not exceeding 70 º C.
3 Water temperature (recommended no more than plus 70 ° C) should not exceed 100 º C. plus


 

Basic technical data :


1 worker agent - water. Inlet pressure of 0.2-0.6 MPa. Outlet Pressure max, MPa 22.
2 Performance of one pump, t / h, max 38
3 Number of pumps 2
4 Internal diameter of the  inlet connection, 80 mm
5 The maximum size of the particles after filtration of 0.2 mm
6 Installed capacity of one pump unit, 45 kW
7 Dimensions, mm Length 2150 Width 1900 Height 1590
8 Weight pumping station, kg, not more than 2082
9 Contents of non-ferrous metals, weight, kg: - Copper - 6.4 (wire).